Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT.
about
Filtered backprojection formula for exact image reconstruction from cone-beam data along a general scanning curve.Reconstruction of 3D regions-of-interest from data in reduced helical cone-beam scans.Image reconstruction in peripheral and central regions-of-interest and data redundancy.Handling data redundancy in helical cone beam reconstruction with a cone-angle-based window function and its asymptotic approximation.A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT.Region of Interest Imaging for a General Trajectory with the Rebinned BPF AlgorithmHigh-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data.Image reconstruction in reduced circular sinusoidal cone-beam CT.A simplified Katsevich algorithm motivated by the distribution properties of k-lines.L0 constrained sparse reconstruction for multi-slice helical CT reconstruction.Parallel Implementation of Katsevich's FBP Algorithm.Region-of-interest image reconstruction with intensity weighting in circular cone-beam CT for image-guided radiation therapy.Half-Fan-Based Intensity-Weighted Region-of-Interest Imaging for Low-Dose Cone-Beam CT in Image-Guided Radiation Therapy.BPF-type region-of-interest reconstruction for parallel translational computed tomography.A promising limited angular computed tomography reconstruction via segmentation based regional enhancement and total variation minimization.A filtered backprojection algorithm for triple-source helical cone-beam CT.Exact Weighted-FBP Algorithm for Three-Orthogonal-Circular Scanning Reconstruction.PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch.An approximate short scan helical FDK cone beam algorithm based on nutating curved surfaces satisfying the Tuy's condition.Region-of-interest image reconstruction in circular cone-beam microCT.Chord-based image reconstruction in cone-beam CT with a curved detector.Exact BPF and FBP algorithms for nonstandard saddle curves.Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): performance studies.
P2860
Q30983092-AE5BD452-3CAB-4BCD-9A91-42BC8F40C2E1Q30985050-C5B5F521-2583-4243-BFD5-C4AC18FC19FCQ30987578-CA6E716C-DB9E-47BF-BB2D-1B647DE104A1Q31119861-071AFCE8-9BB5-4699-BA36-4AB3EA588FF8Q33571712-ED73693F-1D4A-4EE7-8ED7-E1FE4FEA0D41Q33967551-FFE5A255-635F-431A-8153-7BAFF6766B03Q34047207-214ED5FF-1CFE-4A0C-AE56-19DA1A1D6E38Q34626236-1BBEA5D6-DD51-4EC1-BA4C-AAC19B08B4D1Q35171960-19079348-A989-4B03-9E59-684CCD374D1DQ35866410-543DDD63-9893-463E-A021-991CA0DB23FEQ36572437-6FFFB27B-E493-41AE-ACD5-163C9B8DB6A0Q37170425-9B975737-8F0E-4FF4-9E53-54A09F2E95F3Q37424616-C76D94B0-5480-4828-8BE0-147680D7D75FQ38981370-2AB4970C-844E-4C0B-864C-06822FC7375BQ39429996-0629F6E7-077E-4F35-837A-ADC19ADE9BC1Q40767701-15EA401C-3594-40C9-8029-95269DBF255BQ41911562-25B8B59C-30DF-42D0-BE82-387741E3FD14Q44456351-7FBB62BF-E683-4CE3-AB8D-CD108D6DA581Q45050814-CFE51030-A8D8-4A72-B1AF-1C6AC8DDD677Q47976011-D315C6A6-6714-4883-82A6-44810FB45033Q51107836-CB195024-8338-41DB-BE7D-C0804309DEA6Q51300142-FE11C6AB-2079-42C5-BF10-F7FAB7F683C4Q51653332-C80E1754-84C2-49CA-8188-44A06A6A168A
P2860
Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT.
description
2004 nî lūn-bûn
@nan
2004年の論文
@ja
2004年学术文章
@wuu
2004年学术文章
@zh
2004年学术文章
@zh-cn
2004年学术文章
@zh-hans
2004年学术文章
@zh-my
2004年学术文章
@zh-sg
2004年學術文章
@yue
2004年學術文章
@zh-hant
name
Image reconstruction on PI-lin ...... ction in helical cone-beam CT.
@en
Image reconstruction on PI-lin ...... ction in helical cone-beam CT.
@nl
type
label
Image reconstruction on PI-lin ...... ction in helical cone-beam CT.
@en
Image reconstruction on PI-lin ...... ction in helical cone-beam CT.
@nl
prefLabel
Image reconstruction on PI-lin ...... ction in helical cone-beam CT.
@en
Image reconstruction on PI-lin ...... ction in helical cone-beam CT.
@nl
P356
P1476
Image reconstruction on PI-lin ...... ction in helical cone-beam CT.
@en
P2093
P304
P356
10.1088/0031-9155/49/12/017
P577
2004-06-01T00:00:00Z