Role of electrode placement as a contributor to variability in cochlear implant outcomes.
about
Procedural Factors That Affect Psychophysical Measures of Spatial Selectivity in Cochlear Implant Users.Clinical evaluation of an image-guided cochlear implant programming strategy.Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral ThresholdsInvestigation of the effect of cochlear implant electrode length on speech comprehension in quiet and noise compared with the results with users of electro-acoustic-stimulation, a retrospective analysis.Vowel and consonant confusions from spectrally manipulated stimuli designed to simulate poor cochlear implant electrode-neuron interfaces.Design and evaluation of a cochlear implant strategy based on a "Phantom" channel.The Relationship Between Insertion Angles, Default Frequency Allocations, and Spiral Ganglion Place Pitch in Cochlear Implants.Measurement of Cochlear Implant Electrode Position From Intraoperative Post-insertion Skull Radiographs: A Validation Study.Benefits to Speech Perception in Noise From the Binaural Integration of Electric and Acoustic Signals in Simulated Unilateral Deafness.Use of the Phantom Electrode strategy to improve bass frequency perception for music listening in cochlear implant users.Cochlear implants: system design, integration, and evaluation.Identifying cochlear implant channels with poor electrode-neuron interface: partial tripolar, single-channel thresholds and psychophysical tuning curves.Impact of electrode design and surgical approach on scalar location and cochlear implant outcomesPitch Discrimination: An Independent Factor in Cochlear Implant Performance Outcomes.A novel perfusion-based method for cochlear implant electrode insertion.Round window electrocochleography just before cochlear implantation: relationship to word recognition outcomes in adults.Electrophysiologic consequences of flexible electrode insertions in gerbils with noise-induced hearing loss.Binaural fusion and listening effort in children who use bilateral cochlear implants: a psychoacoustic and pupillometric study.Probing the electrode-neuron interface with focused cochlear implant stimulationTransitioning from bimodal to bilateral cochlear implant listening: speech recognition and localization in four individuals.Implications of minimizing trauma during conventional cochlear implantation.Semiautomatic cochleostomy target and insertion trajectory planning for minimally invasive cochlear implantation.A manually operated, advance off-stylet insertion tool for minimally invasive cochlear implantation surgery.Binaural benefit with and without a bilateral spectral mismatch in acoustic simulations of cochlear implant processing.Current steering with partial tripolar stimulation mode in cochlear implantsSurgery of the ear and the lateral skull base: pitfalls and complications.Intraoperative round window recordings to acoustic stimuli from cochlear implant patients.Monopolar intracochlear pulse trains selectively activate the inferior colliculus.Sequential bilateral cochlear implantation in a patient with bilateral Ménière's disease.Use of an adaptive-bandwidth protocol to measure importance functions for simulated cochlear implant frequency channels.Cochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulationPre-, per- and postoperative factors affecting performance of postlinguistically deaf adults using cochlear implants: a new conceptual model over timePlace-pitch manipulations with cochlear implants.Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis.Imaging in cochlear implant patientsPartial tripolar cochlear implant stimulation: Spread of excitation and forward masking in the inferior colliculus.Modeling the electrode-neuron interface of cochlear implants: effects of neural survival, electrode placement, and the partial tripolar configuration.Development and evaluation of the modiolar research array--multi-centre collaborative study in human temporal bones.Depth of electrode insertion and postoperative performance in humans with cochlear implants: a histopathologic study.Consensus panel on a cochlear coordinate system applicable in histologic, physiologic, and radiologic studies of the human cochlea
P2860
Q26784304-5E18D6E7-33E5-40D2-88C8-90E9240A227DQ27345304-082F05A2-1A5A-44E4-881E-C54213294BCCQ30355180-27571FA5-E4C3-43FD-B99B-D29AEFC40EB8Q30355753-74330AB8-C787-481F-8D25-D621DABBFF99Q30358500-C5025703-25A2-48F4-ABDD-442A50279E1BQ30373010-B757FFF3-D155-447E-940D-CF7A4C1F6888Q30375171-6EB9A603-9DF1-4DEF-AFD0-8AA5D2437FF1Q30375450-5E5820B2-8D71-4E7D-A6F3-231E54A9BBD9Q30381126-7AA08242-CDCA-42E7-84C0-FF943D62E58DQ30381287-5066374B-1C7B-47BE-B34E-483C01F4685FQ30382987-8CAE2CB1-4FC0-4E15-862D-859B6342DC45Q30384671-FA752732-82FB-4143-9E2B-F92620D8B7EAQ30399967-3DC20ABF-05EA-4FA7-BA88-598F0FD05141Q30401411-B5C7DF14-955E-4C20-A836-F06D3FB6070DQ30405677-67193DF8-647B-4289-AF98-82EDE3268568Q30410853-EA9E4766-F996-4714-B17A-0B06C1ACE7BDQ30415759-AFD92B7C-1A69-4FB1-8889-B61FA33CBFFEQ30418541-3E3F76B4-8D9A-4178-9AE8-A52EC28F462EQ30424903-DF01A325-E8A2-4DF7-BB9F-B5CBCCD5FE70Q30428605-D8449D56-58DC-46DC-86EC-E034A6D512E2Q30433228-6DED2BAF-FE27-4E2B-9EA0-4DF74F848250Q30433280-F24A5D78-AECF-4089-B2C1-F4473D8B1D39Q30435414-D7F1988E-0FD8-40C7-B000-C1DA54E23740Q30439072-1756572B-7F49-45E6-91F1-3BF8E33472BFQ30440848-DD477068-24BE-4D05-9682-242FF61477D2Q30444643-DE5630E2-1C6D-49B1-AAC8-B1EB450FC0A5Q30446690-B58F9780-AB1B-43F9-8CF3-5ADB8CA7FC81Q30448686-825D6B56-2DD8-45EA-AEB2-96B3783BD919Q30455864-E8B4A7D7-81E4-410E-BB99-54DB50A746D5Q30458617-58DC7F1C-425A-458D-8669-78E1F51781D0Q30459516-53576992-132F-4DCB-913A-0158FD32ABAFQ30460968-6B08BCE7-76F7-47EB-9E04-8630B0E9B2B5Q30464131-F098A534-F2CA-40B4-AE8E-6A51692351D2Q30465302-C1B839C5-3310-4F85-A60C-0F2EA2B1FD10Q30467844-363B41F1-A30A-47D9-A8C5-2F5C4FF5DCA8Q30472528-6A5319DD-D48B-4BD8-8983-03E7D5330C96Q30474294-1BDB291D-0053-4CAD-BCCA-0F08DDFFDC81Q30474468-8FCA29FD-C0A5-4CB1-BF3D-49FFC9B3C02EQ30474906-E3C8C193-2B5B-4B7F-9AD4-5415AAFEFBFDQ30474986-3F8065D5-B256-4A71-86C2-7E468E53A540
P2860
Role of electrode placement as a contributor to variability in cochlear implant outcomes.
description
2008 nî lūn-bûn
@nan
2008 թուականի Հոկտեմբերին հրատարակուած գիտական յօդուած
@hyw
2008 թվականի հոտեմբերին հրատարակված գիտական հոդված
@hy
2008年の論文
@ja
2008年論文
@yue
2008年論文
@zh-hant
2008年論文
@zh-hk
2008年論文
@zh-mo
2008年論文
@zh-tw
2008年论文
@wuu
name
Role of electrode placement as a contributor to variability in cochlear implant outcomes.
@ast
Role of electrode placement as a contributor to variability in cochlear implant outcomes.
@en
type
label
Role of electrode placement as a contributor to variability in cochlear implant outcomes.
@ast
Role of electrode placement as a contributor to variability in cochlear implant outcomes.
@en
prefLabel
Role of electrode placement as a contributor to variability in cochlear implant outcomes.
@ast
Role of electrode placement as a contributor to variability in cochlear implant outcomes.
@en
P2093
P2860
P1476
Role of electrode placement as a contributor to variability in cochlear implant outcomes.
@en
P2093
Bruce R Whiting
Charles C Finley
Gail J Neely
Laura K Holden
Margaret W Skinner
Richard A Chole
Timothy A Holden
Timothy E Hullar
P2860
P304
P356
10.1097/MAO.0B013E318184F492
P577
2008-10-01T00:00:00Z