Validation of quantitative bound- and pore-water imaging in cortical bone
about
Cortical bone water concentration: dependence of MR imaging measures on age and pore volume fraction.Bone mineral (31)P and matrix-bound water densities measured by solid-state (31)P and (1)H MRI.Magnetic resonance imaging assessed cortical porosity is highly correlated with μCT porosity.Effects of inversion time on inversion recovery prepared ultrashort echo time (IR-UTE) imaging of bound and pore water in cortical bone.Changes in skeletal collagen cross-links and matrix hydration in high- and low-turnover chronic kidney disease.Identifying Novel Clinical Surrogates to Assess Human Bone Fracture Toughness.The Role of Water Compartments in the Material Properties of Cortical BoneBi-component T2 * analysis of bound and pore bone water fractions fails at high field strengths.In Vivo Quantitative MR Imaging of Bound and Pore Water in Cortical Bone.A Surrogate Measure of Cortical Bone Matrix Density by Long T2 -Suppressed MRIVolumetric Cortical Bone Porosity Assessment with MR Imaging: Validation and Clinical Feasibility.Selective in vivo bone imaging with long-T2 suppressed PETRA MRI.MRI-derived bound and pore water concentrations as predictors of fracture resistanceSolid-State Quantitative (1)H and (31)P MRI of Cortical Bone in Humans.Measurement of bound and pore water T1 relaxation times in cortical bone using three-dimensional ultrashort echo time cones sequences.Fast volumetric imaging of bound and pore water in cortical bone using three-dimensional ultrashort-TE (UTE) and inversion recovery UTE sequences.Advances in imaging approaches to fracture risk evaluation.30-Second bound and pore water concentration mapping of cortical bone using 2D UTE with optimized half-pulses.UTE imaging with simultaneous water and fat signal suppression using a time-efficient multispoke inversion recovery pulse sequence.Non-destructive NIR spectral imaging assessment of bone water: Comparison to MRI measurements.Cortical Bone Porosity: What Is It, Why Is It Important, and How Can We Detect It?Stress fractures of the foot and ankle, part 1: biomechanics of bone and principles of imaging and treatment.Simple and robust saturation-based slice selection for ultrashort echo time MRI.Bone volume-to-total volume ratio measured in trabecular bone by single-sided NMR devices.
P2860
Q30818198-E7D634F7-4E4C-4FDE-943C-97437902426EQ30824972-C4BDB986-89D5-4CD4-B867-CCB148E98D34Q30831057-82C5DD89-2E59-4E1C-942C-492CD1F31B9BQ30864245-24AAEB1D-CDEF-48F6-9671-AB89BB151B18Q30873913-0A434384-8071-4470-8AE9-5DA76F103F32Q30886905-5B615C04-DB4F-44A5-9B87-D0F400CDE878Q30911933-1EA0776C-66AE-49B5-8E24-F6F7B01BC527Q30952904-75F9501B-C9A2-4D09-AF25-13DE312AE1E2Q30960498-B048D81C-56A9-4CCD-A17C-FD84D63E0FF8Q30974295-6B4F1A60-1367-4421-9B6C-2D9AA4680F85Q30982219-1D735DA3-A4F6-43AF-AAB7-E4D39434DCCFQ31049161-97F4D8AE-E068-4623-BCCF-C38A899D183CQ31060711-B4A5A7A1-D537-4200-938C-43F8622FCC14Q31069297-AE5763FC-96E5-4C07-BA63-9B94095D3F48Q31105705-BDDEBBF1-1DBA-44A0-84D1-DA0998C2D9EAQ31119860-CBDC734F-9507-40F1-A456-FA0E13F3C04DQ31141102-27951CAD-1DB8-4B0C-BD63-4C34D6C08441Q31154828-2286CE84-B37C-4180-A1DA-B80984A96A6CQ38652958-C1E51263-ABBD-47F7-8100-F22F89544CB7Q38699372-69A10FB2-4B83-4406-BCD4-67C21D571B83Q38953355-4FA6B27A-6EC4-4C08-8A84-0C8BD04D3B41Q39217997-59D7403B-1F56-4C72-9768-95A16EF0BD70Q42170000-1C19D160-06FC-4164-962F-8CF2C7D73D65Q48667142-49FB9568-1849-4520-839F-97DB284FE04D
P2860
Validation of quantitative bound- and pore-water imaging in cortical bone
description
2013 nî lūn-bûn
@nan
2013 թուականի Յուլիսին հրատարակուած գիտական յօդուած
@hyw
2013 թվականի հուլիսին հրատարակված գիտական հոդված
@hy
2013年の論文
@ja
2013年論文
@yue
2013年論文
@zh-hant
2013年論文
@zh-hk
2013年論文
@zh-mo
2013年論文
@zh-tw
2013年论文
@wuu
name
Validation of quantitative bound- and pore-water imaging in cortical bone
@ast
Validation of quantitative bound- and pore-water imaging in cortical bone
@en
type
label
Validation of quantitative bound- and pore-water imaging in cortical bone
@ast
Validation of quantitative bound- and pore-water imaging in cortical bone
@en
prefLabel
Validation of quantitative bound- and pore-water imaging in cortical bone
@ast
Validation of quantitative bound- and pore-water imaging in cortical bone
@en
P2093
P2860
P356
P1476
Validation of quantitative bound- and pore-water imaging in cortical bone
@en
P2093
Daniel F Gochberg
Jeffry S Nyman
Kevin D Harkins
Mark D Does
Mary Kate Manhard
R Adam Horch
P2860
P304
P356
10.1002/MRM.24870
P577
2013-07-22T00:00:00Z