Accuracy of three automated systems (MicroScan WalkAway, VITEK, and VITEK 2) for susceptibility testing of Pseudomonas aeruginosa against five broad-spectrum beta-lactam agents.
about
Detecting imipenem resistance in Acinetobacter baumannii by automated systems (BD Phoenix, Microscan WalkAway, Vitek 2); high error rates with Microscan WalkAway.Accuracies of beta-lactam susceptibility test results for Pseudomonas aeruginosa with four automated systems (BD Phoenix, MicroScan WalkAway, Vitek, and Vitek 2).Antimicrobial susceptibility testing: a primer for clinicians.Osteomyelitis of the long bones.Assessment of microbiological diagnostic procedures for respiratory specimens from cystic fibrosis patients in German laboratories by use of a questionnaire.Performance of Vitek 2 in antimicrobial susceptibility testing of Pseudomonas aeruginosa isolates with different mechanisms of beta-lactam resistance.Pseudomonas Endocarditis with an unstable phenotype: the challenges of isolate characterization and Carbapenem stewardship with a partial review of the literature.Comparison of an automated system with conventional identification and antimicrobial susceptibility testing.A rapid antimicrobial susceptibility test based on single-cell morphological analysis.Expression of the MexXY-OprM efflux system in Pseudomonas aeruginosa with discordant cefepime/ceftazidime susceptibility profiles.Validation of Vitek 2 nonfermenting gram-negative cards and Vitek 2 version 4.02 software for identification and antimicrobial susceptibility testing of nonfermenting gram-negative rods from patients with cystic fibrosis.Detection of carbapenem resistance in clinical mucoid Pseudomonas aeruginosa isolates.Challenges for accurate susceptibility testing, detection and interpretation of β-lactam resistance phenotypes in Pseudomonas aeruginosa: results from a Spanish multicentre study.Potential Impact of Flow Cytometry Antimicrobial Susceptibility Testing on the Clinical Management of Gram-Negative Bacteremia Using the FASTinov® Kit.Detection of Piperacillin-Tazobactam-Resistant/Pan-β-Lactam-Susceptible Escherichia coli with Current Automated Susceptibility Test Systems.
P2860
Q33418763-CCB7C954-C1F4-4BC9-B009-E06A0333456CQ35784407-BE79FC46-D2C5-4426-A659-DCBEDCEF32CEQ37621552-05DA0CC8-FBC8-4735-BB12-204B17A7F2A4Q37766771-9F1CFE94-C462-4BBC-861A-A1E2833789DDQ38323549-DC0B8C1F-507C-404F-9DC1-6B6B17FFC57EQ39760823-0E691FE9-8504-4121-984E-66B872271963Q40073768-AA525E58-4591-43FB-86C0-77115984978BQ41048460-34074087-568A-4EED-9136-5DFA471F6F94Q41593333-E4E53051-1BA6-47F5-A4FF-57CF47145827Q41843691-795B9231-F716-4E7C-A975-D41B6DB1A929Q41976892-18239B8F-8186-4B62-BD46-98DD6E1B2FACQ43239631-9EBE1871-680B-47D4-B532-C786BDA7F3CDQ46958203-3B289277-BD51-4F19-9E0E-B790EC9D7703Q47178141-5E25E621-6211-419F-83A6-4B971F517710Q47996890-08EE9F59-D4DD-4298-A7A0-C7F5149129D1
P2860
Accuracy of three automated systems (MicroScan WalkAway, VITEK, and VITEK 2) for susceptibility testing of Pseudomonas aeruginosa against five broad-spectrum beta-lactam agents.
description
2006 nî lūn-bûn
@nan
2006 թուականի Մարտին հրատարակուած գիտական յօդուած
@hyw
2006 թվականի մարտին հրատարակված գիտական հոդված
@hy
2006年の論文
@ja
2006年論文
@yue
2006年論文
@zh-hant
2006年論文
@zh-hk
2006年論文
@zh-mo
2006年論文
@zh-tw
2006年论文
@wuu
name
Accuracy of three automated sy ...... d-spectrum beta-lactam agents.
@ast
Accuracy of three automated sy ...... d-spectrum beta-lactam agents.
@en
Accuracy of three automated sy ...... d-spectrum beta-lactam agents.
@nl
type
label
Accuracy of three automated sy ...... d-spectrum beta-lactam agents.
@ast
Accuracy of three automated sy ...... d-spectrum beta-lactam agents.
@en
Accuracy of three automated sy ...... d-spectrum beta-lactam agents.
@nl
prefLabel
Accuracy of three automated sy ...... d-spectrum beta-lactam agents.
@ast
Accuracy of three automated sy ...... d-spectrum beta-lactam agents.
@en
Accuracy of three automated sy ...... d-spectrum beta-lactam agents.
@nl
P2860
P1476
Accuracy of three automated sy ...... d-spectrum beta-lactam agents.
@en
P2093
Ronald N Jones
Thomas R Fritsche
P2860
P304
P356
10.1128/JCM.44.3.1101-1104.2006
P407
P577
2006-03-01T00:00:00Z